OUTLET - 120 VAC, 230 VAC and 277 VAC
Power Outlets (Female Connectors) to supply power to the AIRIUS SYSTEM should
always be installed by a qualified electrician or similarly qualified person in
accordance with national and local electrical codes.
The AIRIUS SYSTEM uses very little AMPERAGE (less than 1 amp) thus multiple outlets
may be installed on one circuit. Outlets are available in many configurations, check
with the local Electrical Contractor to determine preferred type for the facility. Outlets
should generally be mounted vertically unless a “twist/locking” type is being used.
Facilities with Fire suppression systems installed often have a master cutoff switch to
Shut-off all power in the event of a fire or emergency. The electrical circuits for the
AIRIUS SYSTEM should be wired through that Shut-off. Always use and review the
National / Local Electrical Codes when installing the AIRIUS SYSTEM in ANY Facility.
DO NOT wire the AIRIUS SYSTEM into the Lighting circuit, as the system will cycle
on and off with the lights, greatly reducing the
systems effect
iveness.
The AIRIUS SYSTEM is designed to operate 24 Hours-a-Day, 7 Days-a-Week (24/7) for
the maximum results.
PLUG - 120 VAC, 230 VAC and 277 VAC
120 VAC cord is supplied with a molded three prong polarized /grounded plug
DO NOT DEFEAT this SAFETY DEVICE or modify the plug in any way.
230/277 VAC (International market) no plug supplied. When fitting a plug always
ensure that all relevant local regulations/electrical codes are understood and followed
with care - if in any doubt seek expert guidance.
Procedure for Wiring the Plug in a Single-Phase Electrical System
Use CAUTION when wiring/attaching the Plug (Male Connector) to the AIRIUS
SYSTEM or when using any Electrical Device.
1. Plug should be rated for 230 VAC (277VAC) or greater and fit properly
into Outlet (Female Connector) being used to deliver power.
2. To avoid electrical shock, DO NOT plug device into Energized Outlet
until all exposed wires, and connecting terminals, are enclosed by
Plug Housing. See Plug Manufacturer's Instructions.
3. Locate the (3) stripped wires on the 300
VAC
Rated Power Cord
attached to the AIRIUS SYSTEM where the outer cord insulation
jacket has been removed. Wires are coded as follows:
Brown or Black is HOT/Positive/LIVE (the energized/electrified
conductor) Blue or White is Neutral “N” (the conductor used for a
return current path) Yellow-Green or Green is Ground/Earth (the
conductor to connect to the Earth)
4. Using the Plug Manufacturer's Instructions, Locate the proper
positions to attach the color-coded wire to the color-coded or
otherwise appropriately labeled terminals on the Plug.
5. Tighten all connections. Re-assemble plug in accordance with Plug
Manufacturer's Instructions.