Plug Wiring (230/277VAC Models)
120VAC cord is supplied with a molded three prong polarized/grounded plug. DO NOT DEFEAT this SAFETY DEVICE or
modify the plug in any way.
230/277VAC no plug supplied. When fitting a plug always ensure that all relevant local regulations/electrical codes are
understood and followed with care - if in any doubt seek expert guidance.
The power cord is a three wire 18 AWG (or 16 AWG) 300VAC rated electrical cord UL rated in North America (NA) as SJT
or for CE/EU compliance rated as HO5VV.
The three wires in the power cord are color-coded to ensure proper wiring as follows:
BLACK or BROWN = HOT/ELECTRIFIED/LIVE
WHITE or BLUE = “N” NEUTRAL/RETURN PATH
GREEN or YELLOW-GREEN = GROUND/EARTH
The cord is attached to the fan motor via two power leads with insulated 1/4” quick connects.
UNMARKED motor lead - HOT/LIVE
MARKED “N” motor lead - NEUTRAL
GROUND/EARTH is attached to a boss on the outside of the motor housing with a Star Ring #10 terminal and 8-32 x 1/4”
machine screw.
The cord is secured in the housing by a strain relief and knotted inside the housing for additional security.
Procedure for wiring the plug in a single-phase electrical system:
Use CAUTION when wiring/attaching the plug (Male Connector) to the Air Pear system or when using any electrical
device.
1. Plug should be rated for 230VAC or 277VAC and fit properly into outlet (female connector) being used
for power.
2. To avoid electrical shock, DO NOT plug device into Energized Outlet until all exposed wires and connect-
ing terminals are enclosed by plug housing. See plug manufacturer’s instructions.
3. Locate the three stripped wires on the 300VAC rated power cord attached to the Air Pear where the outer
cord insulation jacket has been removed. Wires are coded as follows: black or brown is HOT/Live
(the energized conductor), white or blue is neutral “N” (the conductor used for a return current path)
and green or yellow/green is ground/earth (the conductor to connect to the earth)
4. Using the plug manufacturer’s instructions, locate the proper positions to attach the color-coded wire to
the color-coded or otherwise appropriately labeled terminals on the plug.
5. Tighten all connections. Reassemble plug in accordance with plug manufacturer’s instructions.
To confirm electrical continuity, if possible, plug the Air Pear system into an energized outlet on the ground, similar to the
outlet installed in the ceiling, before permanently mounting the Air Pear system.
NOTE: The Air Pear System can be wired directly to a junction box but only by a qualified electrician or similarly qualified
person. Always ensure that all relevant local regulations/electrical codes are understood and followed with care - if in any
doubt seek expert guidance. Check local electrical codes. The preferred system is designed with a plug for easy service
and cleaning. An on-off switch must be installed in the circuit to be able to disable the power to prevent electrical hazard
when servicing the appliance.